Microwave ablation of liver tumor
 
 
Clinical details:
A patient, who had already undergone TACE, was posted for micro wave ablation of 20mm mass in Segment 5 of the liver
Procedure details
Precise planning was required to reach the deep seated lesion. MAXIO assisted in precisely targeting the lesion without causing
trauma to vital structures. Microwave ablation of the lesion done in
single sitting of ablation. No post procedure complications
Details
Orbital angle: 7.12 deg
Depth: 117.88 mm
Tumor size: 20x17x14 mm
Needle used: 14G / Amica - Needle length 200mm
Number of needles: one
Planning time: 7 min
Procedure time: 15 min
Anesthesia: Local
Accuracy: 1mm
Comments from Clinician:
Good show, you will get good ablated image. Accurate placement of
needle.
Clinician:
Prof Vogl and Dr Zangos, University of Frankfurt, Germany.